DESKRIPSI TUGAS AKHIR :
Rancang Bangun Alat Monitoring Penggunaan Energi Listrik Gedung Terpadu Politeknik Negeri Balikpapan Menggunakan NodeMCU-ESP32 Berbasis Aplikasi Blynk
Abstrak (Abstracts)
The current rapid population growth and industrial activity have resulted in the need and consumption of electricity which continues to increase every year. With the increase in electrical energy consumption every year, savings must be made in accordance with the Regulation of the Minister of energy and Material Resources (ESDM) number 13 of 2012 which states that in order to increase savings in the use of electrical energy, it is necessary to use or use electrical energy efficiently and rationally, without reduce safety, comfort and productivity. Energy data on the power meter displayed through the blynk application, by reading the active energy sent is worth 0.093 kWh, the reactive energy sent is worth 1,688,846 kVARh, the apparent energy sent is 0.102 kVA, the active energy received is -15,588,958 kWh, reactive energy received -373.41 kVARh, apparent energy received -16.373.304 kVA. Based on the Energy Consumption Intensity (IKE) standard for electricity of Indonesia, the Integrated Building IKE in 2022 is still below the safe limit, for office buildings, which is 240 Kwh/m^2/year. Pertumbuhan jumlah penduduk dan kegiatan industri yang pesat saat ini mengakibatkan kebutuhan dan konsumsi listrik yang terus meningkat tiap tahunnya. Dengan pertambahan konsumsi energi listrik disetiap tahunnya, harus dilakukannya penghematan sesuai dengan Peraturan Mentri Energi dan Sumber Daya Mineral (ESDM) nomor 13 tahun 2012 menyatakan bahwa dalam rangka peningkatan penghematan penggunaan energi listrik, perlu dilakukan pemakaian atau penggunaan energi listrik secara efisien dan rasional, tanpa mengurangi keselamatan, kenyamanan dan produktivitas. Nilai data energi pada power meter yang ditampilkan melalui aplikasi blynk, dengan pembacaan pada energi aktif delivered bernilai 0,093 kWh, energi reaktif delivered bernilai 1.688,846 kVARh, energi semu delivered bernilai 0,102 kVA, energi aktif received bernilai -15.588,958 kWh, energi reaktif received -373,41 kVARh, energi semu received -16.373,304 kVA. Intensitas Konsumsi Energi (IKE) listrik Gedung Terpadu pada tahun 2022 berada pada level 52,73 Kwh/m^2/tahun. Berdasarkan standar Intensitas Konsumsi Energi (IKE) listrik untuk indoneisa, maka IKE Gedung Terpadu pada tahun 2022 masih berada di bawah batas aman gedung perkantoran yaitu 240 Kwh/m^2/tahun.

Keyword : Keywords: power meter, NodeMCU-ESP32, Energy Consumption Intensity (IKE), monitoring.

Nilai Properti
: ADE NAFIQ NUR ARI, : 982019009, : Politeknik Negeri Balikpapan, : Teknologi Listrik, : 2022, : Indonesia, : Tugas Akhir, : Prepustakaan Poltekba,

 

Download Full Text
Pembimbing
Hilmansyah, S.T., M.T.

E-mail :hilmansyah@poltekba.ac.id

www.poltekba.ac.id
Angga Wahyu Aditya,S.ST., M.T.

E-mail :

www.poltekba.ac.id
https://www.elementbike.id/data/selotgacorku/https://karanganbungacilacap.com/https://vclass.unila.ac.id/blog/sdana/https://sipolahta.dispermadesdukcapil.jatengprov.go.id/fontawesome-free/-/slot186/https://dupak.dinkes.jatimprov.go.id/public/storage/-/https://simawa.upnvj.ac.id/uploads/temp/smaxwin/https://e-learning.uniba-bpn.ac.id/rahasia/https://www.elementbike.id/product/slot186/https://bpiw.pu.go.id/image/scatter/http://lms.sipil.ft.unand.ac.id/layouts/https://e-learning.universitasbumigora.ac.id/local/maxclub/